E144782
The high-voltage service disconnect is
located behind the rear fold down seats.
Disabling the High-Voltage Battery
1. Fold down the rear seats.
2. Locate the access door and remove
the plastic cover.
3. A cut out area will be visible which
allows your hand access to the service
disconnect.
E147234
4. Slide the handle on the service
disconnect outboard to the right. Energi
vehicles slide the handle outboard to
the left.
E146133
5. Pull the handle toward you and remove
the service disconnect from the vehicle
to disable the high-voltage battery.
Reverse this procedure the re-install the
service disconnect.
Reactivating the High-Voltage Battery
Note: If you have manually disconnected
the high-voltage service disconnect you will
need to reconnect the service disconnect
before it can be reactivated. The vehicle will
detect if the electrical system is safe and
reactivate automatically.
HIGH VOLTAGE BATTERY CUT-
OFF SWITCH
The high-voltage shut off operation shuts
off power from the high-voltage battery
after a collision, or if your vehicle receives
a substantial physical jolt.
To reactivate the vehicle after either event
perform the following steps:
1. Turn the ignition off.
2. Turn the ignition on.
3. If the vehicle is not powered after this
sequence, repeat steps 1 and 2.
For vehicles equipped with a push button
start system:
1. Press the START/STOP button to
turn ignition off.